{"product_id":"elitech-refrigerant-leak-detector-eld-270-portable-high-sensitivity-sniffer-2-g-yr-flexible-probe","title":"Elitech Refrigerant Leak Detector ELD-270 — Portable High-Sensitivity Sniffer, 2 g\/yr, Flexible Probe","description":"\u003cp\u003e\u003cstrong\u003eThe Elitech ELD-270 is a portable, high-sensitivity refrigerant leak detector that locates halogenated and hydrocarbon refrigerant leaks down to 2 g\/year with audible, visual and vibration alerts.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe ELD-270 combines a heated diode sensor, adjustable sensitivity levels and a flexible probe to help HVAC technicians and automotive service professionals quickly find refrigerant leaks in tight or noisy environments. It supports a wide range of refrigerants including R134A, R410A, R1234YF, R600a and many CFC\/HCFC\/HFC\/HFO blends, and arrives ready for fieldwork with a blow-molded case, spare filters and a calibration certificate.\u003c\/p\u003e\n\n\u003ch3\u003eHow precise is the ELD-270 at finding small leaks?\u003c\/h3\u003e\n\u003cp\u003eThe detector offers ultra-high sensitivity capable of detecting leaks as small as 0.07 oz\/year (approximately 2 g\/year). A numeric digital display (0–9) and three adjustable sensitivity modes make it straightforward to home in on the exact leak location.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eDetection limit: ~2 g\/year (0.07 oz\/year).\u003c\/li\u003e\n  \u003cli\u003eDigital leak level readout from 0 to 9 for quick assessment.\u003c\/li\u003e\n  \u003cli\u003eThree sensitivity settings to trade off reach vs. noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat features help the ELD-270 perform reliably on the job?\u003c\/h3\u003e\n\u003cp\u003eBuilt with a heated diode sensor and an integrated pump-suction design, the unit improves response speed and sensitivity while resisting moisture with an anti-water-absorption function. It meets CE and EN14624 standards for refrigerant leak detectors and warms up within 30 seconds with response times around 3 seconds.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eHeated diode sensor for extended service life and stable output.\u003c\/li\u003e\n  \u003cli\u003eAnti-moisture protection and pump-suction design for better uptake.\u003c\/li\u003e\n  \u003cli\u003eCertified to CE and EN14624 for professional use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow does the ELD-270 make locating leaks easier in real-world conditions?\u003c\/h3\u003e\n\u003cp\u003eThe unit provides audible, visual and vibration alarms so you can detect leaks even in noisy or cramped spaces. A bendable probe accesses tight joints and hard-to-reach fittings, and an included UV lamp and spare filters expand its practicality on diverse jobsites.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eTriple alert modes: sound, LED and vibration for noisy environments.\u003c\/li\u003e\n  \u003cli\u003eFlexible probe reaches confined components and valves.\u003c\/li\u003e\n  \u003cli\u003eAccessories include UV lamp, five filter elements, and blow case.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat are the runtime and maintenance expectations for this detector?\u003c\/h3\u003e\n\u003cp\u003eThe ELD-270 runs for up to seven hours on a single charge, suitable for a full day of inspections with intermittent use. Routine maintenance is straightforward: replace filter elements as needed and follow the enclosed calibration certificate schedule to preserve accuracy.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eUp to 7 hours continuous runtime per charge for field work.\u003c\/li\u003e\n  \u003cli\u003eReplaceable filters and accessible sensor for simple upkeep.\u003c\/li\u003e\n  \u003cli\u003eCalibration certificate supplied to verify performance standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eWho is this for: The Elitech ELD-270 is aimed at HVAC service technicians, automotive A\/C specialists and facilities maintenance teams who need a portable, standards-compliant refrigerant leak detector capable of identifying both halogenated refrigerants and hydrocarbons in tight or noisy environments. It’s useful for routine leak checks, post-repair verification and preventive maintenance where sensitivity, durability and clear alerts are important.\u003c\/p\u003e\n\u003csection class=\"product-faq-snippet\"\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: Which refrigerants does the ELD-270 detect?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: It detects R134A, R410A, R1234YF, R600a and most halogenated and hydrocarbon refrigerants including CFCs, HCFCs, HFCs and HFOs.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: How long does the detector run between charges?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: The ELD-270 provides up to about seven hours of continuous operation on a full charge under typical field conditions.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e","brand":"Elitech","offers":[{"title":"Default Title","offer_id":55172590240087,"sku":"B0GRV7F2CM","price":139.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/1524\/7191\/files\/elitech-eld-270-front-view.jpg?v=1790452858","url":"https:\/\/britishgarage.co.uk\/products\/elitech-refrigerant-leak-detector-eld-270-portable-high-sensitivity-sniffer-2-g-yr-flexible-probe","provider":"British Garage","version":"1.0","type":"link"}