{"product_id":"tigbear-r1234yf-refrigerant-charge-hose-kit-59-low-side-hose-250-psi-gauge-puncture-can-tap","title":"Tigbear R1234YF Refrigerant Charge Hose Kit — 59\" Low‑Side Hose, 250 PSI Gauge, Puncture Can Tap","description":"\u003cp\u003e\u003cstrong\u003eThe Tigbear R1234YF Refrigerant Charge Hose Kit is a complete low‑side charging solution with a puncture can tap, 250 PSI gauge, and 59\" hose for safe, accurate R1234YF and R134a refrigerant top‑ups.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThis compact, workshop‑ready kit is built for technicians and DIYers who need to add refrigerant to vehicle or appliance low‑side ports. It combines a durable 59\" rubber hose, a large 250 PSI pressure gauge legible at a glance, a 14 mm low‑side quick coupler with six sealing balls, and a puncture‑style can tap designed for 1\/2\" LH R1234YF cans. Components are brass and high‑grade rubber for corrosion resistance and reliable sealing under repeated use.\u003c\/p\u003e\n\n\u003ch3\u003eHow does this kit keep refrigerant from venting during service?\u003c\/h3\u003e\n\u003cp\u003eThe Tigbear kit incorporates a built‑in safety valve and an auto‑closing quick coupler to minimize accidental leaks. The puncture can tap opens only compatible puncture‑style R1234YF cans while the quick coupler’s six‑ball seal locks tight to the low‑side port.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eSafety valve prevents uncontrolled release when disconnecting.\u003c\/li\u003e\n  \u003cli\u003e6 sealing balls on the quick coupler for secure low‑side connection.\u003c\/li\u003e\n  \u003cli\u003eAuto close function reduces chance of refrigerant loss when detached.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCan I use this hose kit for both R1234YF and R134a systems?\u003c\/h3\u003e\n\u003cp\u003eYes — the Tigbear hose and gauge read pressures for R1234YF and R134a, making it flexible for many vehicles and appliances. Note that the included low‑side adapters and the puncture can tap are specifically sized for R1234YF puncture cans with a 1\/2\" LH thread and will not work with self‑sealing cans.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eGauge calibrated up to 250 PSI for accurate R1234YF readings.\u003c\/li\u003e\n  \u003cli\u003eHose rated for 600 PSI working pressure and 3000 PSI burst for safety.\u003c\/li\u003e\n  \u003cli\u003eAdapters designed specifically for R1234YF low‑side fittings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat makes the gauge and hose reliable during garage or roadside use?\u003c\/h3\u003e\n\u003cp\u003eThe gauge is large and easy to read, and the 59\" hose gives freedom to reach charge ports without awkward positioning. Brass fittings resist corrosion, and the heavy‑duty rubber hose withstands normal shop use while meeting industry pressure ratings.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eLarge readable 250 PSI gauge face for quick pressure checks.\u003c\/li\u003e\n  \u003cli\u003e59\" hose length to reach most engine bay charge ports comfortably.\u003c\/li\u003e\n  \u003cli\u003eBrass construction and quality rubber for durability and stable performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow should I use this kit safely and effectively?\u003c\/h3\u003e\n\u003cp\u003eAttach the low‑side quick coupler to the vehicle’s service port, connect the can tap to a compatible puncture‑style R1234YF can, and open the valve slowly while watching the gauge. Add refrigerant incrementally and stop when the system pressure reaches manufacturer guidelines or the gauge's green range; if there is no cooling, seek professional diagnosis.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eOnly puncture R1234YF cans with 1\/2\" LH thread using the can tap.\u003c\/li\u003e\n  \u003cli\u003eAdd refrigerant gradually and monitor pressure and system performance.\u003c\/li\u003e\n  \u003cli\u003eIf the system won’t cool after charging, consult a professional technician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eWho this is for: The Tigbear R1234YF Refrigerant Charge Hose Kit suits vehicle owners who do routine A\/C topping‑off, mobile mechanics, and appliance technicians who need a portable, accurate low‑side charging setup. It’s best for users familiar with basic A\/C service procedures and who understand when to stop charging and call a shop for deeper troubleshooting.\u003c\/p\u003e\n\u003csection class=\"product-faq-snippet\"\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: Is the can tap compatible with self‑sealing R1234YF cans?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: No. The can tap works only with puncture‑style R1234YF cans that have a 1\/2\" LH thread.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\"\u003e\n\u003cp class=\"faq-q\"\u003eQ: What pressure ratings does the hose and gauge have?\u003c\/p\u003e\n\u003cp class=\"faq-a\"\u003eA: Gauge reads up to 250 PSI; hose rated 600 PSI working and 3000 PSI burst pressure.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/section\u003e","brand":"Tigbear","offers":[{"title":"Default Title","offer_id":55165637099863,"sku":"B0F2FNNSBH","price":35.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/1524\/7191\/files\/tigbear-front-packaging.jpg?v=1790356773","url":"https:\/\/britishgarage.co.uk\/products\/tigbear-r1234yf-refrigerant-charge-hose-kit-59-low-side-hose-250-psi-gauge-puncture-can-tap","provider":"British Garage","version":"1.0","type":"link"}